Output variables, Sysout1 to 15, #genout1 to 18, #handout1 to 4, Down timer : #downtimer1 to 10 – Loctite CARTESIAN 400 User Manual

Page 33

Advertising
background image

Output variables:

#sysOut1 to 15, #genOut1 to 18, #handOut1 to 4


Output variables are Boolean variables.
Output variables corresponds to the I/O-SYS, I/O-1, and I/O-H output pins. When an ON signal is
output, the output variables become “1” (true).

Identifier

(JS Series)

Identifier

(Cartesian)

Category

Connector Description

#sysOut1 to 14

#sysOut1 to 16

I/O-SYS

Boolean variable

#genOut1 to 18

#genOut1 to 8

I/O-1

Boolean variable

Output

variable

#handOut1 to 4

I/O-H Boolean

variable



#sysOut1 to 16 (I/O-SYS) are assigned a function in advance.

Ex) #sysOut1: Ready for Start (ON signal: Operation can be started)

If you want to use #sysIn1 to 16 (I/O-SYS) for a function other than the one to which it has been
assigned, switch the run mode parameter setting to free. (I/O-SYS function assignment)

Down timer : #downTimer1 to 10


Numeric variable. When assigned (let) a value, counting down in msec units starts automatically. A
value can also be assigned during countdown.
The maximum value that can be assigned is 2,147,483,647 (msec).

Category

Identifier

Description

Special

variable

When a value is assigned, counting down (in msec units)
starts automatically.

#downTimer1 to 10

Features II CARTESIAN Benchtop Robot

15

Advertising