[ Condition ]

Condition Settings: ld, ldi, and, ani, or, ori, anb, orb


The following describes the condition commands placed after the If Branch, Wait Condition (if,
waitCond, waitCondTime) commans. The command category it belongs to is [Condition.]

Command

Category

Command

Parameter

Job

Boolean variable or expression

ld

ON input

ldi

Boolean variable or expression

OFF input

and

Boolean variable or expression

Serial ON input

ani

Boolean variable or expression

Serial Off input

or

Boolean variable or expression

Parallel ON input

ori

Condition

Boolean variable or expression

Parallel OFF input

anb

Block serial connection

orb

Block parallel connection


I/O-SYS output (#sysOut), I/O-1 output (#genOut), I/O-H output (#handOut), system flag (#sysFlag),
internal relay (#mv), keep relay (#mkv), and pallet flag, as well as I/O-SYS input (#sysIn), I/O-1 input
(#genin), and I/O-H input (#handIn), can be given as command parameters.
Comparison operation expressions can also be used. Variables and functions other than the above
parameters can also be used in comparison operation expressions.

Comparison

operation expression

Meaning

Comparison

operation expression

Meaning

<=

=

Equal

to

=<

greater than or equal

to

<

greater than

>=

=>

less than or equal to

>

less than

<>

><

Not equal


A comparison operation expression must always start from an Id or Idi command line. If it is only an
independent ON (true) or OFF (false) condition, it is a 1 line command, but when multiple conditions
are connected with and, or, etc., it becomes a multi-line command string.
Expressions can also be used in conditional operations. In this case, the result of the expression is
judged as 0 (flag) or nonzero (true).