Waiting for a start instruction: waitStart, waitStartBZ


This section explains the point job data commands to stop running until a start instruction is received.

Command Category

Command Parameter

Job

Stands by in place until a start instruction
is received.

waitStart

-

Delay, Data In,

Stands by in place while sounding an
alarm buzzer until a start instruction is
received.

Wait Start

waitStartBZ

-

The commands “waitStart” and “waitStartBZ” are invalid at the CP Passing Point or a point
whose Base Type is CP Passing Point.


waitStart: Wait for start.
Example)

set #genOut1
waitStart
reset #genOut1

Outputs an ON signal to #genOut1.
Stands by in place until a start instruction comes.
Outputs an OFF signal to #genOut1 (when a start instruction is
received.)


waitStartBZ: Wait for start (alarm buzzer)
For Example: If #genIn1 does not come ON within 2 seconds, it is recognized as an error, genOut2
(connected to an external alarm/error lamp) comes ON and the robot “stands by for start while
sounding an alarm buzzer.”

When an operator resolves the problem and sends a start instruction, the OFF signal will be
output to #genOut2 and the operation will start from Point 05.

waitCondTime 2000
ld #genIn1

Wait for #genIn1 to go ON for 2 seconds.

timeUp
upZ 50,20
set #genOut2
waitStartBZ
reset #genOut2
goPoint PTP3,5
endWait

If #genIn1 does not come ON within 20 seconds,
Raise the Z axis 50 mm (at the speed of 20 mm/sec),
Output ON signal to #genOut2,
Sound an alarm buzzer and stand by in place until a start instruction is

received.

Output OFF signal to #genOut2 (when a start instruction comes),
Go to Point 05.
End of the comannd which will be executed if #genIn1 does not come
ON within 20 seconds.