Landmark Lighting D20R2-06/99 User Manual

Page 59

Advertising
background image

Function

Code

Minimum Level Required

Notes

N

R

U

C

A

SECURITY

240

X

X

READ (or higher) lets users access
the Security Definitions Menu.
UPDT (or higher) is required to
change the type of logon and
function security used.

SHUTDOWN

003

X

SIGNON

001

X

STORANAL

106

X

STORTCBS

221

X

STORTIOT

220

X

STRGALTR

211

X

Works with the STRGNPRV and
STRGPRV functions. To alter
private storage, READ access must
be specified for STRGALTR and
UPDT must be specified for
STRGPRV. To alter nonprivate
storage, READ access must be
specified for STRGALTR and UPDT
must be specified for both
STRGPRV and STRGNPRV.

STRGDSPY

137

X

Works with the STRGNPRV and
STRGPRV functions. To display
private storage, READ access must
be specified for both STRGDSPY
and STRGPRV. To display
nonprivate storage, READ access
must be specified for both
STRGDSPY and STRGNPRV.

STRGNPRV

115

X

X

Works with the STRGDSPY,
STRGALTR, and STRGPRV
functions. To alter nonprivate
storage, you must be authorized to
alter private and nonprivate
storage. See the above notes for
the STRGDSPY and STRGALTR
functions for the authorization
required to display and alter
nonprivate storage.

STRGPRV

116

X

X

Works with the STRGDSPY and
STRGALTR functions. See the
above notes on these functions for
the authorization required to display
and alter private storage.

SUPERTRC

109

X

X

READ (or higher) lets users view
Supertrace data. To start
Supertrace collection for the
selected job(s), UPDT (or higher)
must be specified for the JOBLIST
function.

SYSADMIN

111

X

X

UPDT (or higher) is required to
update data collection options in the
System Administration option.

TASKCANC

118

X

Chapter 2: Security Definitions

Function Access Level Table

The Monitor for MVS 2.0

2-43

System Administrator’s Guide