OPERATION

SET UP MENU

Many additional parameters can be modified via the
Set Up Menu. To access the Set Up Menu:

• Position the ON/OFF switch to OFF “0”.

• Depress and hold the Parameter select Push Button.

• Position the On/Off switch to on "I" at the back of the

machine; the input voltage light "Item 1" (green LED)
confirms normal operation.

• The SETUP mode is confirmed by a center "0" on the

Digital display “Item 6”.

- Rotate the Output / Parameter Adjust Knob,

the Digital Display shows the numbers corre-
sponding to the parameters in sequence;
stop at the desired parameter and push the
"Setup/Parameter Push Button".

- The number on the Digital display "Item 6" is

replaced by the value of the parameter that
can be modified through the Output /
Parameter adjust knob "Item 5".

- With parameter (9) all the modifications

made in the SETUP mode are cancelled and
the standard values set by Invertec V205-T
AC/DC are restored.

- To exit the Set Up Menu, return to “0” and

press the Setup/Parameter Push Button

INDICATOR

PARAMETER

DEFAULT

0

Exit From Set Up

1

Not Used

2

Pre Flow Time (0 - 25 seconds)

0.5 sec.

3

Arc Force, percent above Peak Current for Stick only (0 - 100%)

30%

4

Hot Start, percent above Peak Current for Stick only (0 - 100%)

80%

5

Setting of AC wave Form

2 (Square)

0 = Sinusoidal
1 = Triangular
2 = Square

NOTE: This parameter limits maximum weld current, see "OUTPUT LIMITATIONS" section of the manual.

6

Min. Weld Current Value with Remote Control,for TIG only.

10 Amps

(6 Amps - Value set for Indicator 7)

7

Max. Weld Current Value with Remote Control,for TIG only.

Peak Current

(Value set for Indicator 6 - Peak Current)

NOTE: Peak Current (Max Weld Current) can be limited by input voltage, welding mode, AC TIG waveform and AC TIG frequency.

8

Touch Start or H.F. Start in DC TIG (0 = H.F. Start, 1 = touch Start)

0

This parameter is ignored in AC TIG Mode

9

Reset all Parameters, (including control panel settings)

10

Not Used

11

Not Used

12

2 Step Trigger Selection

1

0 = Restart Disabled
1 = Restart Enabled

13

4 Step Trigger Selection

0

0 = Restart Disabled
1 = Restart Enabled

14

Start Power , for TIG only

2.0

This function sets the initial start energy limit.

(1.0 = min., 5.0 = max.)

Note: If the machine does not initiate a welding arc it will repeat the

starting sequence with an increased start energy up to this limit.

Set this number to a higher setting than the factory default if
needed to improve starting of large diameter tungstens electrodes.