TROUBLESHOOTING & REPAIR

CONTROL/DISPLAY BOARD TEST (CONTINUED)

F-26

F-26

V205-T AC/DC

Retur

n to Section TOC

Retur

n to Section TOC

Retur

n to Section TOC

Retur

n to Section TOC

Retur

n to Master TOC

Retur

n to Master TOC

Retur

n to Master TOC

Retur

n to Master TOC

FIGURE F.10 PLUGS CN1, CN2 & CN7

CN2

41

1

2

3

4

42

45

CN1

44

1

2

3

4

7

8

6

5

48

52

53

54

CN7

2

3

5

6

73

76

1

4

72

71

58

TABLE F.2 PLUG CN1 TEST POINTS

TABLE F.3 PLUG CN2 TEST POINTS

TABLE F.4 PLUG CN7 TEST POINTS

Wire #

52

53

54

44

48

58

Description

Solenoid Valve Ground

Trigger

Trigger

Start High Frequency

High Frequency Ground

Start Solenoid Valve

Expected Voltage

-------

-------

-------

-------

-------

48 VDC

Wire #

71

72

73

74

75

76

Description

Ext

Ext

Ext Ground

Ext Trigger

Ext Ground

Ext Ground

Expected Voltage

5 VDC

-------

-------

-------

-------

-------

Wire #

41

42

45

Description

Supply

Supply

Ground for Supplies

Expected Voltage

24 VDC

48 VDC

-------