Troubleshooting and repair, Secondary power board, Secondary power board test (continued) – Lincoln Electric Invertec V205-T User Manual

Page 76

Advertising
background image

TROUBLESHOOTING AND REPAIR

SECONDARY POWER BOARD TEST (continued)

F-40

F-40

V205-T AC/DC

Retur

n to Section TOC

Retur

n to Section TOC

Retur

n to Section TOC

Retur

n to Section TOC

Retur

n to Master TOC

Retur

n to Master TOC

Retur

n to Master TOC

Retur

n to Master TOC

TEST PROCEDURE

1. Remove input power to the V205-T machine.

2. Using a phillips head screwdriver, remove the

case wraparound cover.

3. Perform the Capacitor Discharge Procedure

detailed earlier in this section.

4.

Locate the Secondary Power board and asso-
ciated plugs . Do not remove plugs from the
board.
See Figure F.19.

5.

Carefully apply the correct input voltage to the
V205-T and check for the correct secondary
voltages per Table F.13.

FIGURE F.19 SECONDARY POWER BOARD LOCATION