The machine is dead—no fan –no output—no leds, The main input fuses or breakers repeatedly fail, Troubleshooting & repair – Lincoln Electric Invertec V205-T User Manual

Page 40: Caution

Advertising
background image

Retur

n to Section TOC

Retur

n to Section TOC

Retur

n to Section TOC

Retur

n to Section TOC

Retur

n to Master TOC

Retur

n to Master TOC

Retur

n to Master TOC

Retur

n to Master TOC

V205-T AC/DC

TROUBLESHOOTING & REPAIR

F-4

F-4

Observe Safety Guidelines

TROUBLESHOOTING GUIDE

detailed in the beginning of this manual.

CAUTION

If for any reason you do not understand the test procedures or are unable to perform the test/repairs safely, con-
tact the Lincoln Electric Service Department for electrical troubleshooting assistance before you proceed. Call
1-800-833-9353(WELD).

OUTPUT PROBLEMS
(SYMPTOMS)

POSSIBLE AREAS OF
MISADJUSTMENT(S)

RECOMMENDED
COURSE OF ACTION

OUTPUT PROBLEMS

Major physical or electrical damage
is evident when the sheet metal
cover(s) are removed.

1. Contact your local authorized

Lincoln Electric Field Service
Facility for assistance.

1. Contact the Lincoln Electric

Service Department 1-800-833-
9353.

The machine is dead—no fan –no
output—no LEDs.

1. Make sure the input power

switch is in the ON position.

2. Check the main input fuses. If

open replace.

3. Make sure the correct input volt-

age is applied to the machine.

1. Check the input power switch for

proper operation. Also check the
associated leads for loose or
faulty connections. See wiring
diagram.

2. Perform the Input Filter Board

Test.

The main input fuses or breakers
repeatedly fail.

1. Make certain the fuses or break-

ers are properly sized for the
input draw of the machine.

2. The welding procedure may be

drawing too much input current
or the duty cycle may be too
high. Reduce the welding cur-
rent and/or reduce the duty
cycle.

1. The Input Filter Board may be

faulty. Perform the Input Filter
Board Test.

2. The Main IGBT Inverter Board

may be faulty. Perform the
Main IGBT Inverter Board Low
Voltage Supply Test.

Advertising