Troubleshooting & repair – Lincoln Electric Invertec V205-T User Manual

Page 68

Advertising
background image

Retur

n to Section TOC

Retur

n to Section TOC

Retur

n to Section TOC

Retur

n to Section TOC

Retur

n to Master TOC

Retur

n to Master TOC

Retur

n to Master TOC

Retur

n to Master TOC

TROUBLESHOOTING & REPAIR

F-32

F-32

V205-T AC/DC

MAIN INVERTER BOARD “UPFR” SECTION TEST (continued)

TEST PROCEDURE

1. Remove input power to the V205-T machine.

2. Using a phillips head screwdriver, remove the

case wraparound cover.

3. Perform

the

Capacitor Discharge

Procedure detailed earlier in this section.

4.

Locate the UPFR section on the main board
and associated plugs. Do not remove
plugs from the board.
See Figure F.14.

5.

Carefully apply the correct input voltage to
the V205-T and check for the correct sec-
ondary voltages per tables F.10 & F11.
Voltage readings were taken with a Fluke
RMS meter. See Figure F.15 for joint loca-
tions.

FIGURE F.14 UPFR LOCATION ON MAIN BOARD

BACK SIDE

MAIN BOARD

TABLE F.10 VOLTAGE CHECKS WITH 115 VAC APPLIED TO MACHINE

Generator/Mode

ON/STICK

ON/STICK

ON/STICK

ON/STICK

ON/STICK

ON/STICK

ON/STICK

Component

DD1

MF8

MF8

MF9

MF9

-------

TP20-TP9

Ref. Joint

A[-],K[+]

S[-],D[+]

S[-],G[+]

S[-],D[+]

S[-],G[+]

L10 (LED)

-------

Value

250-260 VDC

125 VDC

2.2 VDC

120 VDC

2.2 VDC

ON

385 VDC +/-5V

Generator/Mode

OFF

OFF

Component

F1

R82

Ref. Joint

-------

-------

Value

<1 OHM

46 OHM

TABLE F.11 RESISTANCE CHECKS

Advertising