background image

TIME-DELAY CIRCUIT BREAKER

OR FUSE SIZE (AMPS)

30A

A-2

A-2

V205-T AC/DC

Retur

n to Section TOC

Retur

n to Section TOC

Retur

n to Section TOC

Retur

n to Section TOC

Retur

n to Master TOC

Retur

n to Master TOC

Retur

n to Master TOC

Retur

n to Master TOC

INSTALLATION

Input Amps

34A
28A
20A

34A
25A
20A

30A
23A
19A

30A
18A
15A

Type of Output

AC/DC

Output Amps Volts at Rated Amperes

(Stick) 110

24.4V

90

23.6V

70

22.8V

(TIG) 150

16V

120

14.8V

100

14V

(Stick) 180

27.2V

150

26V

130

25.2V

(TIG) 200

18V

170

16V

140

15.6V

Maximum Open

Circuit Voltage

54 Volts Max.

Input Voltages / 50 /60 Hz.

115

230

Duty Cycle

(115V) 35%

60%
100%

(115V) 40%

60%

100%

(230V) 35%

60%

100%

(230V) 40%

60%

100%

Output Current

Range

6-200 Amps

INPUT - SINGLE PHASE ONLY

RATED OUTPUT

OUTPUT

Height

Width

Depth

Weight

15 in.

8.5 in.

19 in.

Approx. 38 lbs.

381 mm

216 mm

483 mm

17 kgs.

PHYSICAL DIMENSIONS

TECHNICAL SPECIFICATIONS - V205-T AC/DC TIG K1855-1 (Code Number 10860)

TEMPERATURE RANGES

OPERATING TEMPERATURE RANGE

-20°C to +40°C

STORAGE TEMPERATURE RANGE

-50°C to +85°C

INPUT

VOLTAGE /

FREQUENCY

(HZ)

115/50/60

230/50/60

TYPE S, SO ST, STO, OR EXTRA

HARD USAGE INPUT CORD AWG

#12

Max. Input Current

34A at Rated Output
30A at Rated Output

RECOMMENDED INPUT WIRE AND FUSE SIZES FOR MAXIMUM RATED OUTPUT