CONNECTION OF THE LN-25 TO THE
CLASSIC II USING K867 UNIVERSAL
ADAPTER (SEE FIGURE C.3.)

1. Shut the welder off.

2. Connect the electrode cable from the LN-25 to the

“+” terminal of the welder. Connect the work cable
to the “CV-” terminal of the welder.

NOTE: Welding cable must be sized for current and

duty cycle of application.

NOTE: Figure C.3 shows the electrode connected for

positive polarity. To change polarity, shut the
welder off and reverse the electrode and work
cables at the Classic II output terminals.
Reverse the LN-25 polarity switch.

3. Connect the K867 Universal adapter to the K432-L

cable and the 14 pin amphenol of the Classic II as
indicated in Figure C.3.

4. Connect the K433 to the LN-25. Mount the K433

to the welder according to instructions included
with the K433 kit.

5. Place the IDLER switch in the "HIGH" position.

Any increase of the high idle engine RPM by changing
the governor setting or overriding the throttle linkage
will cause an increase in the AC auxiliary voltage. If
this voltage goes over 140 volts, wire feeder control
circuits may be damaged. The engine governor set-
ting is preset at the factory — do not adjust above
RPM specifications listed in this manual.

6. Adjust wire feed speed and voltage at the LN-25.

INSTALLATION

C-6

C-6

CLASSIC II

Retur

n to Section TOC

Retur

n to Section TOC

Retur

n to Section TOC

Retur

n to Section TOC

Retur

n to Master TOC

Retur

n to Master TOC

Retur

n to Master TOC

Retur

n to Master TOC

CAUTION

FIGURE C.3

CLASSIC II/LN-25 CONNECTION DIAGRAM

Classic II Output
Terminals are on
Opposite Side

Splice Leads and Insulate

Insulate Each
Unused Lead
Individually

TO
WORK

14 PIN
AMPHENOL

SPARE

82
81
42
41
21

32

31

32

31

2

2

4

4

75
76
77

75
76
77

GND

GND

K432-"L" CABLE

LN-25 WIRE FEEDER
WITH K431 OPTION

K867 UNIVERSAL
ADAPTER PLUG

ELECTRODE CABLE

CV-

+

K433