TROUBLESHOOTING & REPAIR

F-8

F-8

CLASSIC II

Observe Safety Guidelines

TROUBLESHOOTING GUIDE

detailed in the beginning of this manual.

CAUTION

If for any reason you do not understand the test procedures or are unable to perform the test/repairs safely, con-
tact the Lincoln Electric Service Department for electrical troubleshooting assistance before you proceed. Call
216-383-2531 or 1-800-833-9353.

PROBLEMS
(SYMPTOMS)

POSSIBLE AREAS OF
MISADJUSTMENT(S)

RECOMMENDED
COURSE OF ACTION

FUNCTION PROBLEMS

The engine will not return to low
idle when the welding and auxiliary
loads are removed.

1. Make sure the Idler Control

switch is set to the Auto position.

2. Make sure both welding and

auxiliary loads are removed.

3. Check for mechanical restric-

tions in the idle and throttle link-
age.

1. Check the Idler Control switch

and associated leads for loose
or faulty connections. See the
Wiring Diagram.

2. Check the reed switch CR2. It

may be stuck closed. Replace if
necessary.

3. Check for loose or faulty con-

nections at the Idler PC board.

4.

Make sure lead #60D is
grounded correctly.

5. Perform the

Idler Solenoid

Test.

6. The Idler PC board may be

faulty. Replace.