INSTALLATION

A-2

A-2

CLASSIC II

TECHNICAL SPECIFICATIONS - CLASSIC II

INPUT - DIESEL ENGINE

Manufacturer Description

Speed

Displacement

Ignition

Capacities

Deutz

3 cyl.,

1725 RPM

125 cu. in.

Electric

Fuel: 15 gal.

F3L-1011F

Air-cooled

Full load

(2049 cc)

(57 liters)

diesel

Oil: 6.3 qt.

28 HP @

1800 RPM

(6.0 liters)

1700 RPM

High idle

1350 RPM

Low idle

RATED OUTPUT - WELDER

Duty Cycle

Amps

Volts at Rated Amperes

100% Duty Cycle

200 DC Constant Current

28V

60% Duty Cycle

250 DC Constant Current

40V

40% Duty Cycle

300 DC Constant Current

32V

OUTPUT - WELDER AND GENERATOR

Welding Ranges

Max. Open Circuit Voltage

Auxiliary Power

(1)

40-325 Amps DC

98.5

3.0 kVA of 115/230 V, 60Hz Power

26 Amps @ 115 V

13 Amps @ 230 V

PHYSICAL DIMENSIONS

Height

Width

Depth

Weight

49.94 in.

24 in.

60 in.

1340 lb.

1040 mm

610 mm

1524 mm

608 kg

1

CSA machines can draw 15 amps from either half of the receptacle. Non-CSA machines can draw 20 amps from either half of the
receptacle. Total combined load of all receptacles cannot exceed 3.0 kVA.