Troubleshooting & repair, Shunt field winding test (continued) – Lincoln Electric CLASSICII SVM125-A User Manual
Page 68
Advertising
TROUBLESHOOTING & REPAIR
F-18
F-18
CLASSIC II
SHUNT FIELD WINDING TEST
(continued)
FIGURE F.4 – PLUG P10 LOCATIONS
PLUG P10
TEST PROCEDURE
1. Turn engine off.
2. Unlatch, lift and secure the right side door.
Note that there are latches at both ends of
the door.
3. Locate plug P10. See Figure F.4.
4. Remove plug P10. See Figure F.4.
5. Locate the blue lead (U, pin 3) and the
brown lead (N, pin 5) in the harness plug.
See