Alarm terminal connection, Rs-232c connection, Ps • data connection – Panasonic WJ-HD100 User Manual

Page 13: Data connection, Recall out recover out reset in in, Data

Advertising
background image

13

8

7

6

5

4

3

2

1

REMOTE/ALARM IN

CONTROL IN
ALARM OUT
RECOVER OUT
RESET IN

G

G

G

G

G

G

G

G

G

G

G

+24V

NC

NO

To Alarm
Indicator

External device

NC: Normally Closed
NO: Normally Open

Relay

ALARM

G

RECALL

OUT

RECOVER OUT

RESET IN

IN

Digital Disk Recorder
WJ-HD100

Alarm Terminal Connection

A connection example is shown below.

IN:

Stands for Alarm Signal In. Connect directly with a
sensor unit or indirectly with a unit having sensor
output capability to the recorder. The recorder
enters alarm recording mode when the alarm signal
(active when low) comes in.

RESET IN:

Receives the reset signal (active when low)

from a connected device.

RECOVER OUT:

Supplies the reset signal when the

RESET IN is received, the [■ STOP] button is
pressed, or the AUTO RESET time elapses.

OUT:

Stands for the status output active until an alarm

is reset.

RECALL:

The alarm history is displayed on the Monitor

every time the external switch is turned on.

GND:

Signal ground

RS-232C Connection

Use an RS-232C cable (not included) as shown below to
connect the RS-232C terminal with a personal computer or
the like. The protocol selection in the COMMUNICATION
SETUP must be set to VCR.

9-pin D-sub connector

(female)

9-pin D-sub connector

(female)

1

2

3

4

5

6

7

8

Frame

1

2

3

4

5

6

7

8

Frame

Shield

PS

Data Connection

Connect the DATA terminal on the rear panel to a system
component with a modular cable (not included) in the PS

Data chain. The protocol selection in the COMMUNICA-
TION SETUP must be set to PS

DATA. Follow the proce-

dure for unit address setup (page 14, 30) and termination
(page 14).

Panasonic part # WV-CA48 series, RS-485 cables and con-
nectors are recommended for the connection.

TB

TA

RB

RA

RX

TX

GND

GND

DATA

TA

TB

RA
RB

TX

RX

Advertising