Reset pulse polarity 106 reset pulse, Time adjusting 107 time adjusting, Set time 108 set time – Panasonic WJ-HD100 User Manual

Page 23: Auto erasing 109 auto erasing

Advertising
background image

23

Reset Pulse Polarity
106 RESET PULSE

The polarity of the alarm reset pulse is selected in the
SYSTEM SETUP window.
The reset pulse is supplied from an external device with
high or low active signal form to the RESET IN terminal
on the rear panel.

1. Open the system setup window, then move the cursor

to RESET PULSE with the up [▲] or down [▼] button.

2. Select either HIGH or LOW with the JogDial. The default

is HIGH.

HIGH:

Stands for high-active. The recorder stops alarm

recording when a positive pulse is supplied.

LOW:

Stands for low-active.

Time Adjusting
107 TIME ADJUSTING

IN and OUT terminals for a calibration signal are provided
on the TIME ADJUST terminal board on the rear panel. The
master unit supplies the calibration signal to the slaves.
This is convenient for synchronizing the internal clock with
other connected devices. Make certain to connect the IN
and OUT terminals correctly.

1. Move the cursor to TIME ADJUSTING with the [▲] or

[▼] button.

2. Select either MASTER or SLAVE with the JogDial. The

default is SLAVE.

MASTER:

The unit supplies the calibration OUT signal

to the slave units.

SLAVE:

The internal timer of the unit is supplied the cali-

bration signal from the master.

1. Move the cursor to AUTO ERASING with the [▲] or [▼]

button.

2. Select the desired day number with the JogDial.

OFF:

Auto erasing is not applied.

1DAY:

Only today’s records of 0:00 onward are protect-

ed. Records before 24:00 of yesterday are erased.

2

to

10DAYS:

Records before the specified number of

days are erased.

14, 30, 45, 60, 90, 120, 150, 180DAYS:

Same as

above.

Notes:

• The day number includes today as 1 day, therefore

2DAYS counts today and yesterday in number.

• Auto Erasing is implemented at 24:00 mid night.

Playing back will stop once when the time comes to
24:00, then will restart with different portion based
on the renewed day count.

SYSTEM SETUP

FWD/REW MODE SKIP&PLAY
PASSWORD LOCK OFF
ALL

*****

OPERATION

*****

KEYLOCK BUZZER OFF
RESET PULSE

HIGH

TIME ADJUSTING SLAVE
SET TIME

9:00

AUTO ERASING OFF

Set Time
108 SET TIME

This setting specifies the hour for the master unit to supply
the Time Adjust OUT signal to the slave units once a day.
You need not set the hour when SLAVE is selected. The
slave unit accepts the signal through the IN terminal, and
corrects its internal clock to the hour as far as the clock
deviates within 15 minutes after or before the hour.

1. Move the cursor to SET TIME with the [▲] or [▼] button.

2. Select the desired time (00:00 to 23:00) with the

JogDial.

3. Press the JogDial.

Auto Erasing
109 AUTO ERASING

The redundant records on the disk can be erased every
day at 24:00 mid night. Day numbers specified by this set-
ting means that the records stored during the number of
days from the present will be protected, while the older
records than that of the protected day will be erased.

SYSTEM SETUP

FWD/REW MODE SKIP&PLAY
PASSWORD LOCK OFF
ALL

*****

OPERATION

*****

KEYLOCK BUZZER OFF
RESET PULSE HIGH
TIME ADJUSTING

SLAVE

SET TIME

9:00

AUTO ERASING OFF

SYSTEM SETUP

FWD/REW MODE SKIP&PLAY
PASSWORD LOCK OFF
ALL

*****

OPERATION

*****

KEYLOCK BUZZER OFF
RESET PULSE HIGH
TIME ADJUSTING SLAVE
SET TIME

9:00

AUTO ERASING

OFF

Advertising