Powerware E.T.N 1500 VA - 60kVa User Manual

Page 44

Advertising
background image



EATON CORPORATION Reference Guide & Price Book

SINGLE-PHASE SERIES 9
Powerware 9155 (continued)

OUTPUT RECEPTACLES AND MAINTENANCE BYPASS

Order Number

Description

Dimensions (H x W x D, inches)

Weight (lb)

List Price

See PDM worksheet below:

Power Distribution Module (PDM) with Mechanical

16.5 x 12 x 7

25

$999

Bypass Switch (rear UPS mount)

Receptacle Codes

(Qty) NEMA Type

(Select digits 9-12 in the CTO number)

Price Adder

PDM WorkSheet CTO

Description

Voltage

Phase

per Receptacle Code Chosen

S

Mechanical Bypass Module only

$999

A

(4) 5-15R

120V

Single

$220

B

(4) 5-20R UL

120V

Single

$220

C

(4) 5-20R CSA

120V

Single

$220

D

(4) 6-15R

208V

Dual

$220

E

(4) 6-20R

208V

Dual

$220

F

(4) L5-15R

120V

Single

$220

G

(2) 5-20R*

120V

Single

$220

H

(2) L5-30R*

120V

Dual

$220

I

(2) L6-15R

208V

Dual

$220

J

(2) L6-20R*

208V

Dual

$220

K

(2) L6-30R*

208V

Dual

$220

L

(2) L14-20R*

120/208V

Dual

$220

M

(2) L14-30R*

120/208V

Dual

$220

X

Blank Plate

-

-

$20

0 (Zero)

Last Product Identifier Number

-

-

-

Notes: 1. If any output receptacles are chosen, the Maintenance Bypass module will be included and will add $999 to the cost. 2. Maximum 4 choices within CTO part number (9-12). 3. The combined
quantities of LOCKING receptacles (denoted with a *) must not exceed 4. 4. Please be sure to utilize the "X" designation for any of the 4 total slots not populated. 5. Please contact factory for custom
configuration availability.

POWERWARE 9 OPTIONS

Model Number

Description

Dimensions (H x W x D, inches)

Weight (lb)

List Price

Powerware Hot Sync (Parallel Systems)

124100017-001

9155 Parallel Tie Cabinet

24.0 x 20.3 x 2.2

57.3

$1,499

103004336

CAN Bridge Card

-

-

$519

Note: Up to (3) PW9155s can be paralled within the Parallel Tie Cabinet and each UPS must include a Powerware Hot Sync CAN Bridge Card installed in the 2nd X-Slot.

Extended Battery Module

103004192-5501

PW9155 EBM 64 (2-high Stack)

32.2 x 12.0 x 30.2

480.0

$4,425

103004193-5501

PW9155 EBM 96 (3-high Stack)

47.8 x 12.0 x 30.2

710.0

$7,025

Note: Up to (4) EBM64s or (3) EBM96s can be added for additional runtime.

Maintenance Bypass Module (MBM)

BPE20MBB1A

Wall-mounted Maintenance Bypass Module

21.0 x 14.0 x 6.75

34.0

$1,480

Powerware 9155 Upgrade Packages

See Service Section

PW9155 One-Step kVA Upgrade Kit

See Service Section

PW9155 Two-Step kVA Upgrade Kit

See Service Section

PW9155-2 Unit Parallel Upgrade Kit

See Service Section

PW9155-3 Unit Parallel Upgrade Kit

Notes: An 8 kVA to 15 kVA upgrade would require purchase of a one & two-step upgrade. 2. Up to (3) 9155s can be paralled within the Parallel Tie Cabinet and each UPS must include CAN Bridge Card
installed in the 2nd X-slot. 3. For extended Run-Time Applications, each UPS must have dedicated and identical number of EBMs. 4. Kit Includes CAN Bridge Card and Instructions.

Seismic Kit

103004194-5501

Seismic Kit, Rated Zone 4, UL Tested, Performance rating

136.0

$1,799

based on NEBS GR-63-CORE Standard Vibration Test

SOFTWARE AND CONNECTIVITY OPTIONS

Bundled with Software Suite CD and communication cable. See the software and connectivity section for more details.

SERVICE PLANS

See Service section beginning on page 88 for details.

Powerware 9 Spare Parts

See Service Section PW9155 Spare Parts Kit.

Advertising