Powerware E.T.N 1500 VA - 60kVa User Manual

Page 60

Advertising
background image



EATON CORPORATION Reference Guide & Price Book

THREE-PHASE SERIES 9
Powerware 9355 (10–15 kVA) (continued)

POWERWARE 9 BYPASS CABINETS

Part

Power

Input/Output Dimensions

Weight

List

Model

Number

Rating

Voltage

(H x W x D, inches)

(lb)

Price

PW9355 15kVA 3-Breaker Maintenance Bypass Panel

124100027-001

NA

208V/208V

48 x 20 x 5.8

300

$3,450

(100A Bus, 200A Neutral, & 60A MBP, MIB, MIS)
PW9355 15kVA 3-Breaker Maintenance Bypass Panel

124100027-002

NA

208V/208V

60 x 20 x 5.8

350

$6,548

with integral 120 KA TVSS (100A Bus, 200A Neutral,
& 60A MBP, MIB, MIS)
PW9355 15kVA 3-Breaker Maintenance Bypass Panel

124100027-003

NA

208V/208V

72 x 20 x 5.8

450

$3,850

with 36-Pole Distribution Provisions (Cutler-Hammer GHB 65 kAIC,
GBHW 22 kAIC, & BAB 10 kAIC ONLY)
PW9355 15kVA 3-Breaker Maintenance Bypass Panel

124100027-004

NA

208V/208V

90 x 20 x 5.8

500

$7,100

.

SURGE PROTECTION

See the surge protection product section for more details.

OUTPUT RECEPTACLES

Receptacle Codes

(Qty) NEMA Type

Enter “Receptacle Code” into CTO Digits #

Price Adder for EACH Receptacle Code Chosen

2

(1) L15-30R

9, 10 or 11 only

$220

3

(1) L21-20R

9, 10 or 11 only

$220

4

(1) L21-30R

9, 10 or 11 only

$220

A

(2) 5-15R

9,10,11,12

$220

B

(2) 5-20R UL

9,10,11,12

$220

D

(2) 6-15R

9,10,11,12

$220

E

(2) 6-20R

9,10,11,12

$220

F

(2) L5-15R

9,10,11,12

$220

G

(1) L5-20R*

9,10,11,12

$220

H

(1) L5-30R*

9,10,11,12

$220

I

(2) L6-15R

9,10,11,12

$220

J

(1) L6-20R*

9,10,11,12

$220

K

(1) L6-30R*

9,10,11,12

$220

L

(1) L14-20R*

9,10,11,12

$220

M

(1) L14-30R*

9,10,11,12

$220

X

Blank Panel

9,10,11,12

$20

N

(2) IEC 320 C13 (120V)

9,10,11,12

$220

P

(2) IEC 320 C19 (120V)

9,10,11,12

$220

Note: Arrange receptacle codes in numerical-alphabetical order in digits 9 through 12 of the CTO number

Example 1: a PDM with an L21-20, an L14-30, and Qty 2 IEC320-C19 would have digits 9 through 12 of the CTO arranged as "3MPP"

Example 2: a PDM with a 5-15R, and an L6-30, and an L14-30 would have digits 9 through 12 of the CTO arranged as “AKMX”

The combined quantities of LOCKING receptacles (denoted by *) must not exceed 4 per unit.
Please be sure utilize the "X" designation for any of the 4 total slots not populated.

ON-BOARD CONNECTIVITY OPTIONS

Part Number

Value for

Price

Utilize digit 8 in CTO number

(if ordered seperately)

CTO digit 8

Adder

NONE (No Pre-installed X-Slot card)

0

$0

ConnectUPS-X Web/SNMP Card

3

$335

Modem Card

7

$530

Modbus Card

4

$661

Relay Card (AS/400 compatible)

5

$146

Industrial Relay Card

6

$335

Note: You can have up to two optional connectivity cards installed.

SERVICE PLANS

For service plans, please see the service section beginning on page 88.

Advertising