Precision Trading 60 R3.0 User Manual

Page 12

Advertising
background image

Operator Manual, Supercharger 60

R3.0

Page 12 of 62

3. SPECIFICATIONS

3.1 CHARGE

3.1.1. CONTROL: SCR, air cooled.

3.1.2. MAXIMUM CURRENT: 50 AMPS.

3.1.3. MINIMUM INCREMENT: 0.1 AMP.

3.1.4. ACCURACY and STABILITY of settings: ±1% of reading, ±0.1 AMP.

3.1.4.1. FLOAT:

• The reference voltage is set at the equivalent of 2.33V/cell (Lead-

Acid).

• The Cell Selector provides the basic reference as nominal battery

voltage, e.g.: a 24V battery is entered as 24 on the Cell Selector.

• Current reduction from within 0.5V of the float voltage, with an

accuracy of ±0.5%, ±0.1A

3.1.4.2. PEAK:

• The reference voltage is set at the equivalent of 2.45V/cell (Lead-

Acid).

• The Cell Selector provides the basic reference as nominal battery

voltage, e.g.: a 24V battery is entered as 24 on the Cell Selector.

• Voltage transfer or stop within " 1% of the Peak Voltage.
• Note: Due to cable/connector losses the peak voltage registered by

the Charger-Analyzer will be higher than the actual battery voltage
(up to 0.2V depending on current).

Advertising