Precision Trading 60 R3.0 User Manual

Page 15

Advertising
background image

Operator Manual, Supercharger 60

R3.0

Page 15 of 62

3.2.6. TERMINAL VOLTAGE:

3.2.6.1. Programmable, in accordance with the number of cells selected, at the

equivalent of 1 VOLT/cell.

3.2.6.2. TOLERANCE: ±1% ±0.1 VOLT.

3.2.6.3. NOTE 1: Due to cable/connector losses the voltage registered by the

Charger-Analyzer will be lower than the actual battery voltage (up to
0.2V depending on current).

3.2.6.4. NOTE 2: Terminal voltage is ignored in the full discharge mode.

3.2.7. OVERHEAT PROTECTION:

3.2.7.1. Two thermistors measure the temperature of the bank of discharge

transistors.

3.2.7.2. Operation is terminated if the transistors surface temperature exceeds

90

o

C.

3.2.8. OVER/UNDER CURRENT PROTECTION:

3.2.8.1. A Monitor circuit continuously compares the actual discharge current

with the programmed value

3.2.8.2. Operation is terminated if they differ by more than 1 AMP.

3.2.8.3. NOTE: Undercurrent monitoring is disabled in the full discharge

mode for battery voltages below 2.5V.

3.2.9. REVERSE POLARITY PROTECTION:

3.2.9.1. Operation of the unit is inhibited for reverse voltages greater than 0.5V

3.2.10. FUSING:

3.2.10.1. Aircraft type current limiter, ANN-80(fast).

3.2.10.2. NOTE: The type of limiter and current rating are critical for proper

protection of the discharge circuits. Failure to replace the discharge
current limiter with the proper type/value may result in catastrophic
damage of the load banks.

3.3 TIMER

3.3.1. TIME BASE:

3.3.1.1. Microprocessor Controlled

3.3.2. MODES:

3.3.2.1. NORMAL: Timer advances at the rate of one count per minute

(HH:MM).

3.3.2.2. FAST: Timer advances at the rate of one count per second (MM:SS).

3.3.2.3. TEST: Timer advances at the rate of 60 counts per second (SS:SS/60).

Advertising