Operator Manual, Supercharger 60

R3.0

Page 29 of 62

6.3.4. RUN

6.3.4.1. Start the Charger-Analyzer in the Single Rate mode. The charger will

start to reduce the charging current when the battery voltage is within
0.5V of the float level.

6.3.4.2. The charge will terminate automatically (CYCLE END) when the

TOTAL TIME selected is reached.

6.3.4.3. The charge will terminate as a FAULT if the MONITOR CIRCUIT

detects that:

• Battery temperature exceeds 45

o

C/113

o

F (BATTERY

OVERTEMP FAULT).

• The actual charge current deviates from the programmed value by

more than 1A (CURRENT FAULT).

6.4 PEAK VOLTAGE CHARGE:

6.4.1. Nominal Battery Voltage

6.4.1.1. Enter the nominal battery voltage using the Cell selector (see chart on

page 19).

6.4.1.2. Select transfer from Main to Topping on Peak Voltage or stop on Peak

Voltage.

6.4.2. Charge Currents

6.4.2.1. Program the Main and Topping Charge currents as required.

6.4.3. Time

6.4.3.1. Program the Main and Total Time selectors to allow the battery to

reach the required charge level (consult battery manufacturers
specifications).

6.4.3.2. Verify that the Timer Speed is consistent with the required elapsed

time.

6.4.4. RUN

6.4.4.1. Start the Charger-Analyzer in the Dual Rate mode. If transfer on peak

is selected, the charger will transfer from Main to Topping charge
when the battery reaches the peak voltage. If stop on peak is selected,
the Charger stop upon reaching the peak voltage.

6.4.4.2. The charge will terminate automatically (CYCLE END) when the

TOTAL TIME selected is reached.

6.4.4.3. The charge will terminate as a FAULT if the MONITOR CIRCUIT

detects that:

• Battery temperature exceeds 45

o

C/113

o

F (BATTERY

OVERTEMP FAULT).

• The actual charge current deviates from the programmed value by

more than 1A (CURRENT FAULT).