background image

Operator Manual, Supercharger 60

R3.0

Page 48 of 62

Figure 9 - Monitor Board Adjustments

9.2.4.

MONITOR (see fig 12)

NOTE:

Use pin 14 on the card connector (or the Test Point E0 on the

Control Board) as ground reference for voltage measurements.

9.2.4.1. U12 pin 1 - BATTERY VOLTAGE

• This point corresponds to one tenth of the battery voltage present

at the input terminals.

9.2.4.2. U12 pin 7 - CELL SELECTOR

This point corresponds to one tenth volt per cell,

e.g. 2.00V = 20

cells.