Paradyne 8310 MVLt User Manual

Page 63

Advertising
background image

Monitoring the Hotwire DSLAM

5-7

8000-A2-GB26-10

January 1999

Table 5-2.

Physical Layer Options (4 of 6)

DSL Link Perf (DSL Link Performance Summary)

B-B-D

Displays a summary of the link performance for each of the DSL ports.

Enter port number 1–4 to see the fields for current 15-minute period (real time count of
events during the past 0 to 15 minutes), previous 15-minute period (data updated every
15 minutes), previous 1-hour period (data updated every hour), and 24-hour period (data
is updated every hour).

Port # : – Enter the port number (1–4) you wish to monitor.

Dn Margin – Measure of the noise margin on the specified port in the downstream
direction. A positive margin number reflects a lower error rate with a higher tolerance.

Up Margin – Measure of the noise margin on the specified port in the upstream
direction. A positive margin number reflects a lower error rate with a higher tolerance.

DnErrRate – This statistic is not available for this release and 0 (zero) appears for each
time period.

UpErrRate – Block error rate in the upstream direction. Error rate = bad blocks/good
blocks and is expressed as A x 10

-B

.

DnAttEst – Measure of the downstream transmission loss on the DSL line.

UpAttEst – Measure of the upstream transmission loss on the DSL line.

link dn count – Number of times the DSL link has gone down.

elp lnk up – Count of the elapsed time in seconds that the link has been up.

elp time – Count of the elapsed time in seconds since the DSL card was last reset.

Pct link up – Percentage of time the DSL link has been up in the past 24 hours.