Client cannot reach router, Refer to, Table 6-7 – Paradyne 8310 MVLt User Manual

Page 92: Ipc-to-router segment, And table 6-8, router-to-ipc segment, Go to

Advertising
background image

Diagnostics and Troubleshooting

6-14

8000-A2-GB26-10

January 1999

Client Cannot Reach Router

Table 6-7 examines the IPC-to-Router segment of the network on the IPC end of
the segment.

99-16175-01

O OII

Next Hop

Router

(NHR)

DSLAM

Clients

NMS

WAN

Hub

SN

SN

ISP

IPC

WAN

IPC-to-Router

Segment

NMS

ISP

Gateway

Router

Table 6-7.

IPC-to-Router Segment

Layer

Solution

Layer 1 –
Physical

1. On the IPC, make sure the cables are firmly attached to the WAN

interface.

2. If no CSU/DSUs are being used, either the router or the IPC must

provide network clocking. Network clocking is usually provided by the
device connected to the DCE cables.

3. If no CDU/DSUs exist between IPC and Router, make sure transmission

lines are active by looking for appropriate LEDs.

4. If there is no connection between the router and IPC, invert the clocking

on one or both DSU/CSUs.

Layer 2 –
Network

On the IPC:

1. Set payload scramble to false. To turn PLScramble on or off on the IPC,

type map slot/port (where slot/port is that of the ATM card) and set
10=1 to false.

2. If using SONET, make sure that the line characteristics are correct.

Type map slot/port and select the Phy Media option.

3. Enter vas to make sure a service is configured.

4. Make sure encapsulation is the same as on the router (RFC1483).

5. Enter vvc to make sure vpi and vci are configured correctly.

6. Enter vcs to view ATM connection statistics.

7. Enter vcrs and vcts to view transmitted and received cells.

Advertising
This manual is related to the following products: