Equipment Rack Mounting

To install the unit in an equipment rack:

1. Remove the 12 screws fastening both left and right side plates to the unit. Save the side plates and screws for possible future use.

Figure 5. Remove Left and Right Side Plates

2. Attach the handles to the rack ears using the four provided 10-32 x 0.375-inch Phillips screws. Refer to Figure 6.

3. Using two of the supplied #4 sheet metal Phillips 0.375-inch pan head screws for each side, attach the rack ears to the unit.

(4) SCREWS,
10-32 X 0.375-INCH
PHILLIPS, FLAT HEAD
WITH WASHERS

RACK EAR

(4) SCREWS, #4, SHEET METAL, PAN HEAD,
PHILLIPS BLACK, 0.375-INCH (2 EACH SIDE)

Figure 6. Attaching Rack Ears and Handles

4. Using the remaining six #4 sheet metal Phillips 0.375-inch pan head screws, attach the two chassis brackets to the left and right sides of

the unit. Refer to Figure 7.

5. Assemble both sets of front and rear mounting rails using three 8-32 x 0.375-inch pan head screws and locking washers for each side.

6. Using six of the 10-32 x 0.375 Phillips flat head screws per side, attach the assembled mounting rails to a 19-inch (48.26 cm) equipment

rack or console.

7. Place the unit onto the mounting rails. It should slide in and out of the rack easily. This step may require two persons to lift and slide the

unit into place.

8. Fasten the rack ears to the equipment rack using the four 10-32 x 0.750-inch pan head screws and nylon washers.

You should allow at least one rack unit (1.75 inches or 4.44 cm) of spacing between units. Slots and openings in the cabinet provide
ventilation and prevent the unit from overheating. Do not block these openings. Never place the DVR near or over a radiator or heat
register. Do not place it in a built-in installation, such as a rack, unless proper ventilation is provided.