71

Appendix D: Connecting an Uninterruptible Power Supply (UPS)

If uninterrupted operation is desired and the power grid cannot provide adequate uptime, it is highly recommended that each DX8100 Series DVR
be connected to a UPS device (not supplied). A UPS device will supply a limited amount of battery backup power in the event of a power failure.
Each UPS device should be configured to shut down its corresponding DVR safely during an extended period on battery power.

Only those UPS devices that exhibit the Designed for Microsoft Windows XP logo and are listed on the Windows 2000 Hardware Compatibility
List are approved for use with the DX8100 Series DVR.

WARNING: Do not install on the DX8100 any power management software that may come with your UPS device. The DX8100’s operating
system includes built-in services designed to communicate with UPS devices that exhibit the Designed for Microsoft Windows XP logo.

The following instructions are meant as a general guide for connecting a UPS device to the DX8100 Series DVR. The example below illustrates
the installation of an American Power Conversion UPS. This guide is not intended as a representation of how to install every possible make and
model of UPS device. Follow the directions that came with your UPS device to ensure that the installation process is completed properly.

UPS TO DVR COMMUNICATION AND POWER CONNECTIONS

1. Shut down the DX8100. Refer to Shutting Down for instructions.

2. Connect the UPS to the DX8100 using a standard USB cable.

3. Connect the other end of the USB cable to one of the four USB 2.0 ports on the back panel of the DVR.

4. Connect the power cord of the UPS to a standard wall socket.

5. Connect the power cord of the DX8100 to one of the power outlets on the UPS.

6. Turn the UPS device power switch on.

7. Turn the DX8100 power switch on.

IN1

IN2

IN3

IN4

IN5

IN6

IN7

IN8

IN9

IN10

IN11

IN12

IN13

IN14

IN15

IN16

OUT16

OUT15

OUT14

OUT13

OUT12

OUT11

OUT10

OUT9

OUT8

OUT7

OUT6

OUT5

OUT4

OUT3

OUT2

OUT1

ALARM INPUTS

RELAY OUTPUTS

1 2 2 4 5 6 7 8 GND
9 10 11 12 13 14 15 16

1 2 2 4 5 6 7 8 GND
9 10 11 12 13 14 15 16

POWER
CONNECTION

POWER
CONNECTION

UPS

RS-232

USB CABLE

Figure 94. UPS to DX8100 Connections