Remote administration interface (rai), Guidelines, Installation – Panasonic CPC-EX User Manual

Page 100: Table 5-2, Rai compatibility -6

Advertising
background image

Chapter 5. Peripheral Equipment

Section 300-Installation

5-6

DBS Manual - Revised April 2000

DBS-2.3/9.2-300

Remote Administration Interface (RAI)

Guidelines

• The RAI is a modem card that installs on the SCC card. The card is used to

remotely administer the system through a trunk line.

• Two versions of the RAI card are available. Both versions use 1 Stop bit, 8

data bits, and no parity. The RAI-A card has a fixed baud rate of 300. The
RAI-B card supports both 300 and 1200 baud operation. The following
table shows the transmission rate of each card along with the SCC version
compatibility.

Table 5-2. RAI compatibility

Installation

• Remove the upper cover of the SCC card.

Jumper 1 (J1) on the RAI-B controls the transmission rate. When closed,
the transmission rate is switchable from 300 bps to 1200 bps through
system programming. When open, the rate is fixed at 300 bps.

• Connect the RAI card to the connector on the SCC card.

The RAI-A connects to CN3. RAI-B connects to CN2 and CN3.

• Replace the upper cover of the SCC.

Note: To adjust the output level of the RAI, set switch 4 as shown in
Figure 5-3.

RAI Version/Part No.

Transmission
Parameters

SCC Compatibility

RAI-A (VB-43706)

300 bps, 1 stop bit,
8 data bits, no
parity

SCC-A or SCC-B

RAI-B (VB-43707)

300 bps/1200 bps,
1 stop bit, 8 data
bits, no parity

SCC-B only