Table 4-2. Pinouts and trunk numbers for the main trunk connector.

Trunk Slot

1

1. Trunks connections for a trunk card installed in the EC/TRK slot appear on the Trunk Port Expansion connector
as described on the next page.

Color Code

Pin No.

Desig.

Function

TRK1

(DBS 40,

DBS 72,

DBS 96)

WH-BL

BL-WH

26

1

1T
1R

Trunk 1

WH-OR

OR-WH

27

2

2T
2R

Trunk 2

WH-GN

GN-WH

28

3

3T
3R

Trunk 3

WH-BR

BR-WH

29

4

4T
4R

Trunk 4

WH-SL

SL-WH

30

5

5T
5R

Trunk 5

RD-BL

BL-RD

31

6

6T
6R

Trunk 6

RD-OR

OR-RD

32

7

7T
7R

Trunk 7

RD-GN

GN-RD

33

8

8T
8R

Trunk 8

TRK2

(DBS 72,

DBS 96)

RD-BR

BR-RD

34

9

9T
9R

Trunk 9

RD-SL

SL-RD

35
10

10T
10R

Trunk 10

BK-BL

BL-BK

36
11

11T
11R

Trunk 11

BK-OR

OR-BK

37
12

12T
12R

Trunk 12

BK-GN

GN-BK

38
13

13T
13R

Trunk 13

BK-BR

BR-BK

39
14

14T
14R

Trunk 14

BK-SL

SL-BK

40
15

15T
15R

Trunk 15

YL-BL

BL-YL

41
16

16T
16R

Trunk 16

TRK3

(DBS 96 only)

YL-OR

OR-YL

42
17

17T
17R

Trunk 17

YL-GN

GN-YL

43
18

18T
18R

Trunk 18

YL-BR

BR-YL

44
19

19T
19R

Trunk 19

YL-SL

SL-YL

45
20

20T
20R

Trunk 20

VI-BL

BL-VI

46
21

21T
21R

Trunk 21

VI-OR

OR-VI

47
22

22T
22R

Trunk 22

VI-GN

GN-VI

48
23

23T
23R

Trunk 23

VI-BR

BR-VI

49
24

24T
24R

Trunk 24

VI-SL

SL-VI

50
25

Not used

Advertising