Section 300-Installation

Chapter 6. Double-Cabinet Systems

DBS-2.3/9.2-300

DBS Manual - Revised April 2000

6-3

Guidelines

• Two DBS cabinets can be connected to increase line size. The maximum

line size consists of two DBS 96 cabinets, which provide 192 ports.

• CPC-B and SCC-B are required for two-cabinet systems.

• If ground start or DID trunks are used in both cabinets, separate -48V

supplies must be supplied for each cabinet. If AECs are used in both
cabinets, separate SLT ringer boxes must be supplied for each cabinet.

• The following table shows the acceptable combinations of system types

Table 6-1. Trunk and extension port maximums for double-cabinet systems

• Figures 6-1 through 6-6 shows slot usage for two-cabinet combinations.

System
Combinations

Trunk Extension

Expansion

Ports

Master

Slave

Ports

Ports

(Trunk lines or
extensions)

DBS 40

DBS 40

16

48

8 (See Note 1.)

DBS 72

DBS 40

24

72

0 (See Note 2.)

DBS 72

DBS 72

32

96

8 (See Note 1.)

DBS 96

DBS 40

32

88

16

DBS 96

DBS 72

40

112

16

DBS 96

DBS 96

48

128

16

Notes:

1. The slave cabinet must be used for expansion ports.

2. When a DBS72 and DBS40 are connected, expansion ports cannot be
used.