Figure 4-8 – Panasonic CPC-EX User Manual

Page 72

Advertising
background image

Chapter 4. Trunks and Lines

Section 300-Installation

4-24

DBS Manual - Revised April 2000

DBS-2.3/9.2-300

4. Set SW1 on the T1 card according to the following table.

These switch settings correspond to the distance between the DBS and the
CSU. To turn a switch on, flip it to the “up” position.

Table 4-18. Switch settings for SW1 on the T1 card

5. Install the T1 card in the “EC/TRK” slot

6. Connect the Sync Cable from CN1 on the Sync Unit to CN5 on the T1

card.

Figure 4-8. Sync Unit and T1 connection, single-cabinet installation

7. Connect the cable attached to CN3 on the T1 MDF card to CN3 on the T1

card (Figure 4-10).

8. Using an RJ48 cable, connect CN1 on the T1 MDF card to the CSU

(Figure 4-10). The following illustration shows CN1 pinouts.

SW

Distance from the DBS to the CSU

0 to 150 ft.

150-450 ft.

450-655 ft.

SW1

On

Off

Off

SW2

Off

On

Off

SW3

Off

Off

On

SW4

Off

On

Off

SW5

Off

Off

On

SW6

Off

On

Off

SW7

Off

Off

On

SW8

Not used

Not used

Not used

TR K

D EC

D EC

D EC

D EC

D EC

D EC

D EC

D EC

T1

TR K

SCC

CPC

M FR

N
O
T

U
S
E
D

Sync.U nit

C N 5

C N 1

S .U .

Sync Cable