Chapter 4. Trunks and Lines

Section 300-Installation

4-10

DBS Manual - Revised April 2000

DBS-2.3/9.2-300

Installation

1. Install the G-TRK/8 or DID card in a trunk slot.

2. Connect the power supply by cabling the positive side to the SG

connector on CN2 (Figure 4-4).

Note: Use cables that are 18 AWG or larger to connect the power supply
to the DBS.

Figure 4-4. -48Vpower supply installation

3. Ground the positive side of the -48V power supply to the building

ground.

Note: Resistance to ground must be 10 Ohms or less, and the ground
cable must be 18 AWG or larger.

4. Install power-surge protectors between the wall outlet and the -48V

power supply.

5. Use a standard 50-pin cable to connect the trunks from the MDF to the

main trunk connector CN1.

6. Use a test set to verify the polarity of the trunk.