Table 4-8, T1 slot usage for two-cabinet systems -13 – Panasonic CPC-EX User Manual

Page 61

Advertising
background image

Section 300-Installation

Chapter 4. Trunks and Lines

DBS-2.3/9.2-300

DBS Manual - Revised April 2000

4-13

Table 4-8. T1 slot usage for two-cabinet systems

Fractional T1 can be used when fewer than 24 T1 trunks are needed.

Fractional T1 allows you to use only a portion of the 24 channels provided
on the T1 card.

• Though each T1 Interface provides 24 trunk channels, T1 trunks do not

increase the overall trunk capacity of the DBS. Each T1 channel subtracts
from the total number of analog trunks that can be installed.

• With CPC-B earlier than 5.00, the number of analog trunks that can be

used with Fractional T1 are always decremented in quantities of 8.

For example, if you are installing a T1 in a DBS 96 and you only want to
use 12 T1 channels, the logical number of analog trunks that would be
available is 20 (32 - 12 = 20).

The number of analog trunks must be decremented in quantities of 8, the
actual number of analog trunks that can be used is 16:

(32 total trunks - 16 (two 8-trunk increments) = 16.)

Tables 4-9 through 4-11 show the possible combinations of analog and
digital trunks assignments based on system size.

The trunk numbering shown in these tables is determined by backplane
trunk port assignments. Therefore, the numbering cannot be changed.

• With CPC-B 5.00 and higher and the VB-43511A Loop Start Trunk Card,

the number of analog trunks that can be used with Fractional T1 are
decremented in quantities of 1.

Note: Analog trunks are numbered beginning with “1.” T1 trunk channels
are numbered beginning with the highest trunk channel used.

System Size

EC/TRK Slot Usage for T1

Master

Slave

DBS 40 + DBS 40

No

Yes

DBS 72 + DBS 40

No

No

DBS 72 + DBS 72

No

Yes

DBS 96 + DBS 40

Yes

Yes

DBS 96 + DBS 72

Yes

Yes

DBS 96 + DBS 96

Yes

Yes

Advertising