Voice announce unit (vau), Guidelines, Installation – Panasonic CPC-EX User Manual

Page 116: Table 5-4, Switch settings for sw1, vau -22

Advertising
background image

Chapter 5. Peripheral Equipment

Section 300-Installation

5-22

DBS Manual - Revised April 2000

DBS-2.3/9.2-300

Voice Announce Unit (VAU)

Guidelines

• Operating temperatures for the Voice Announce Unit (VB-43708) should

be between 35 and 105

°

F.

• Maximum loop resistance for the VAU is 10 Ohms.

• The VAU contains a rechargeable lead-acid battery. Recharging circuity

for the battery is included on the VAU.

• The ports used for the VAU must have all FF key assignments cleared

before voice messages and abbreviated dial numbers are programmed.

• The following tools are required to install the VAU:

- Phillips

screwdriver

- Needle-nose

pliers

- Diagonal

shears.

Installation

1. Remove the cover from the Voice Announce Unit.

2. Set SW1 and SW2 according to the following tables. (Default settings are

italicized.)

See Figure 5-14 for the location of the switch blocks.

Table 5-6. Switch settings for SW1, VAU

Switch Block 1 (SW1)

Switch

Function

1

ON=Enable blind transfer

OFF=Disable blind transfer

(VAU chip 1.1 or later is required for blind transfer.)

2

ON=Small DBS

OFF=DBS and DBS 824

3

ON=Two messages up to 16 seconds each

OFF=One message up to 32 seconds