Electrical characteristics, Electrical characteristics -3, Table 7-1 – Panasonic CPC-EX User Manual

Page 145: Input power -3, Table 7-2, Power consumption and heat generation -3, Table 7-3, Battery backup capacity -3

Advertising
background image

Section 300-Installation

Chapter 7. Specifications

DBS-2.3/9.2-300

DBS Manual - Revised April 2000

7-3

Electrical Characteristics

Table 7-1. Input power

Table 7-2. Power consumption and heat generation

Table 7-3. Battery backup capacity

Equipment

Power Requirements

All DBS cabinets

120V AC

± 10 %

60

Hz

DBS key phones

3 watts maximum (powered from the DBS)

System
Status

DB

S 4

0

DB

S 7

2

DB

S 9

6

D

B

S 40 +

DB

S 4

0

D

B

S 72 +

DB

S 4

0

D

B

S 72 +

DB

S 7

2

D

B

S 96 +

DB

S 4

0

D

B

S 96 +

DB

S 7

2

D

B

S 96 +

DB

S 9

6

Power Consumption (in Watts)

With

no

traffic

170 250 320 340 420 500 490 570 640

With

max.

traffic

216 324 444 432 540 648 660 768 888

Heat Generation (Btu per hour)

With no traffic

580

853

1092

1160

1433

1706

1672

1945

2184

With max. traffic

737

1106

1515

1474

1843

2212

2253

2621

3031

System

Battery Pack

Capacity (with maximum traffic)

DBS 40

VB-43130

40 minutes

DBS 72

VB-43130

40 minutes

DBS 96

VB-43130

30 minutes