Table 2-3, Printed circuit package slot usage -8 – Panasonic CPC-EX User Manual

Page 26

Advertising
background image

Chapter 2. System Overview

Section 300-Installation

2-8

DBS Manual - Revised April 2000

DBS-2.3/9.2-300

Printed circuit cards are installed in dedicated slots in the DBS cabinet.
Table 2-3 shows the cards that can be installed in each slot. Figure 2-3 on
page 2-9 il
lustrates slot labels.

Table 2-3. Printed circuit package slot usage

Card Type

Card

Acceptable Slots

Analog

Trunks

L-TRK/4

TRK or EC/TRK

L-TRK/8

G-TRK/8

DID/8

Digital Trunks

T1/24

EC/TRK

Digital Lines

DEC/8

EC 1-8 or EC/TRK

Analog Lines

AEC/8

EC 2-8 or EC/TRK

Service

Circuits

SCC-A SCC

SCC-B

Processor Cards

CPC-A

CPC

CPC-B

CPC-AII

DTMF Circuits

MFR/8

AUX1 or AUX2

CPC (See Note 1.)

Interface Cards

API (1 or 2 Circuits)

AUX1 or AUX2 (See Note 2.)

CBL-M

CPC or AUX2 (See Note 3.)

CBL-S

Notes:

1. With one-cabinet systems, the MFR card can be installed in the AUX1 or AUX2 slot,
depending on whether an API card is used. With two-cabinet systems, placement of the MFR
cards differs according to the cable kit used. With Cable Kit Version 1.1, one MFR is installed
in the Master AUX1, and one MFR is installed in the Slave AUX1. With Cable Kit Version
1.2, both MFR cards are installed in the slave cabinet--one in the CPC slot and one in AUX1.
(See page 6-10 for instructions on installing MFR cards in double-cabinet systems.)

2. The API card is installed in AUX1 only when a CBL card is used.

3. Part VB-43110 includes both the CBL-M and CBL-S cards, as well as the required connect-
ing cables. CBL-M is installed in the master cabinet, CBL-S in the slave cabinet.