Power input connector, External ac universal power supply, Power connection barrel receptacle 5 vdc diagram – Patton electronic 3088A User Manual

Page 16

Advertising
background image

Power input connector

16

Model 3088A Series User Manual

1 • General information

10/100 Ethernet port for management and configuration

Built-in testing and diagnostics

OnSite Plug ‘n’ Play for easy installations

Interoperable with other Patton G.SHDSL modems

Configurable as remote (CP) units

Configurable as central (CO) units to operate back-to-back

Front-panel status indicators

CE marked

Power input connector

The OnSite comes with an AC or DC power supply. (See section

“Power and power supply specifications”

on

page 60.)

The power connection to the CPE is a 2.5 mm barrel receptacle with the center conductor positive
(see

figure 2

).

Rated voltage: 5 VDC

Rated current: 1

A

Figure 2. Power connection barrel receptacle 5 VDC diagram

External AC universal power supply

For additional specifications, see section

“Power and power supply specifications”

on page 60.

Output from power supply: 5 VDC, 2 A

Input to power supply: universal input 100–240 VAC 50/60 Hz 0.3A

The external AC adaptor shall be a listed limited power source
that incorporates a disconnect device and shall be positioned
within easy reach of the operator. Ensure that the AC power
cable meets all applicable standards for the country in which it is
to be installed, and that it is connected to a wall outlet which has
earth ground.

5 VDC

CAUTION

Advertising