External ac universal power supply, External 48 vdc power supply, Transmission line – Patton electronic 3088A User Manual

Page 61: Line coding, Power connection barrel receptacle 5 vdc diagram

Advertising
background image

Transmission line

61

Model 3088A Series User Manual

B • Specifications

Figure 19. Power connection barrel receptacle 5 VDC diagram

External AC universal power supply

Output from power supply: 5 VDC, 2A

Input to power supply: universal input 100–240 VAC 50/60 Hz 0.3A

External 48 VDC power supply

Input

-

Rated voltage: 36–60 VDC

-

Rated current: 0.25 A DC

Output

-

Rated voltage: 5 VDC ± 5%, 5W

-

Rated current: 1 A DC

-

6-inch cable terminated with 2.5 mm barrel plug, center positive

Isolation: 500 VDC

Environment: 0–40°C; 5–95% relative humidity, non-condensing

Transmission line

Single Twisted Pair

Line coding

TC-PAM (Trellis Coded Pulse Amplitude Modulation)

The external AC adaptor shall be a listed limited power source
that incorporates a disconnect device and shall be positioned
within easy reach of the operator. Ensure that the AC power
cable meets all applicable standards for the country in which it is
to be installed, and that it is connected to a wall outlet which has
earth ground.

The external DC adaptor shall be a listed limited power source
that incorporates a disconnect device and shall be positioned
within easy reach of the operator. The interconnecting cables
shall be rated for the proper voltage, current, anticipated tem-
perature, flammability, and mechanical serviceability

5 VDC

CAUTION

CAUTION

Advertising