Dip switch settings – Patton electronic 3088A User Manual

Page 23

Advertising
background image

Introduction

23

Model 3088A Series User Manual

2 • Configuration

DIP switch settings

The following tables provide an overview of the OnSite DIP switch functions.

Table 3. Model 3088A Series - S1 DIP-Switch Functions (Configuration)

Position

Function

(/A, /CA, /D models)

Function

(/K models)

S1-1

Software Reset

Software Reset

S1-2

Reserved

ON - Multiframe
OFF - Fractional/Unframed

a

a. For the Fractional or Unframed setting, both S1-2 and S1-3 must

be set to the OFF position. For the Fractional setting, timeslots
must be set to a value less than 32 (a data rate set at 1984 or less
on DIP switch S4). For the Unframed setting, timeslots must be
set to a value equal to 32 (the 2048 data rate on DIP switch S4).

S1-3

ON - CRC
OFF - Fractional/Unframed

S1-4

Line Coding
ON - HDB3
OFF - AMI

S1-5

DTE/DCE (CO Only)
ON - DTE
OFF - DCE

Reserved (Leave OFF)

S1-6

Annex
ON - Annex B
OFF - Annex A

Annex
ON - Annex B
OFF - Annex A

S1-7

Timing Source (CO only)
ON - Internal
OFF - External (Network)

Timing Source
ON - Internal
OFF - External (Network)

S1-8

DSL Mode
ON - CO
OFF - CPE

DSL Mode
ON - CO
OFF - CPE

Table 4. Model 3088A Series - S3 DIP-Switch Functions (Test Modes and Patterns)

Position

Function

S3-1

Reserved

S3-2
S3-3
S3-4
S3-5

511e Pattern

S3-6

511 Pattern

S3-7

Test Mode Remote

S3-8

Test Mode Local