System reset mode, Dip switch settings, Model 3088a – Patton electronic 3088A User Manual

Page 22: S1 s3

Advertising
background image

Introduction

22

Model 3088A Series User Manual

2 • Configuration

The three sets of DIP switches are externally accessible from the underside of the Model 3088A (see

figure 4

).

Figure 4. Underside of Model 3088A showing location of DIP switches

The three sets of DIP switches on the underside of the Model 3088A are referred to as S1, S3
and S4. For basic configuration, use DIP switch S1. For testing the 3088A, use DIP switch
S3. To configure the rate, use DIP switch S4. This figure shows the DIP switch orientation
with respect to ON and OFF positions is consistent for all switches.

System reset mode

To enter system reset mode, turn the S1-1 DIP switch to the ON position and power cycle the
unit. For information on how to upgrade the software, refer to Chapter 6,

“Software Upgrade”

on page 49. For more information on applying factory default configuration to the 3088A, refer
to Chapter 7,

“Reset configuration to factory defaults”

on page 51.

DIP switch settings

You can configure the 3088A by setting the DIP switches to the desired positions before you
power up the OnSite. If the DIP switches are set to anything other than all OFF or all ON, the OnSite will
operate in DIP switch configuration mode. Once the device is powered up and operating in DIP switch config-
uration mode, you cannot change configuration by any method until you power it down again.

1

2

3

4

5

6

7

8

ON

1

2

3

4

5

6

7

8

ON

S1

S3

Model 3088A

1

2

3

4

5

6

7

8

ON

S4

OFF

ON

1

2

3

4

5

6

7

8

ON

Advertising