Connecting the model 3088a/k serial interface, Connecting the model 3088a/k to an e1 network, Connect twisted pair (120 ohm) to e1 network – Patton electronic 3088A User Manual

Page 37: 120 ohm rj-48c e1 interface, Rj-45 cable diagram for e1 connection

Advertising
background image

Installation

37

Model 3088A Series User Manual

3 • OnSite installation

Connecting the Model 3088A/K serial interface

The Model 3088A/K provides an E1 (G.703/G.704) interface on dual BNC connectors and an
RJ-48C receptacle.

Connecting the Model 3088A/K to an E1 Network
The Model 3088A/K supports E1 network connections. This section describes how to connect the network to
your Model 3088A/K.

Connect twisted pair (120 ohm) to E1 network

The Model 3088A/K is equipped with a single RJ-48C jack for connections to a 120 ohm twisted pair E1 net-
work interface. If your E1 network terminates via RJ-48C, use the diagram below and the table following it to
make the proper connections. The connector pinout and signals are shown in

figure 8

.

Figure 8. 120 Ohm RJ-48C E1 interface

Use the following connection diagram to connect the 120-ohm E1 network channel.

\

Figure 9. RJ-45 cable diagram for E1 connection

The interconnecting cables shall be acceptable for external use
and shall be rated for the proper application with respect to volt-
age, current, anticipated temperature, flammability, and
mechanical serviceability.

CAUTION

1

2

3

4

5

6

7

8

1
2
3
4
5
6
7
8

(RX) Receive (Ring)
(RX) Receive (Tip)
Shield
(TX) Transmit (Ring)
(TX) Transmit (Tip)
Shield
No connection
No connection

Signal Name

RJ-48C Jack

RJ-48C Cable (8-Wire)

E1 (G.703/G.704)

Network signal

3088/K

Signal

Pin #

RX (Ring)

RX (Tip)

Shield

TX (Ring)

TX (Tip)

Shield

1
2
3
4
5
6

TX (Ring)
TX (Tip)
Shield
RX (Ring)
RX (Tip)
Shield

Advertising