How to disconnect, Opening a typical remote console session – Patton electronic 3088A User Manual

Page 47

Advertising
background image

Introduction

47

Model 3088A Series User Manual

5 • Remote console operation

Note

The local or remote 3088A may be CO or CPE, as long as there is one of
each. Either the CO or CPE unit may accept a remote console connection.

Note

With a remote console session open, a user at PC (far-end) is blocked from
using the local console. Upon typing anything, the 3088A (far-end) sends a
message to the PC (far-end) stating Console: Remote console connection is open.

Figure 17 is a screenshot of opening a typical remote console session:

Figure 17. Opening a typical remote console session

How to Disconnect
The remote console session ends under any of the following conditions:

The user enters the command logout

A timeout period of 5 minutes elapses since the user has entered a command to the console.

The DSL link drops.

Log in to 3088 (Near End)

system show status command

shows that DSL link is not up

remote console command requests a

remote console session on 3088 (Far End)

Message informs us that the 3088 (Far End) did not

respond and a remote

console session was not opened
system show status command shows

that the DSL link state is success

remote console command requests a

remote console session on 3088 (Far End)

Message informs us that we are now

connected to the 3088 (Far End) console

We can now enter commands on

the remote console

Advertising