Model 1200

ERV

®

C L E A N • F R E S H • A I R

S P E C I F I C A T I O N S

LATENT RECOVERY (MOISTURE) TRANSFER CORES

Modular (3 section) latent recovery (moisture) transfer cores arranged for
efficient cross-flow ventilation.
MOTORS
Two PSC, 3 speed double shafted, 120 VAC, 4 Amps each (8.1 total on high
speed). HP - 1/4, 1625 RPM. Watts - total on high speed - 972.
FILTERS
Washable air filters in exhaust and supply air streams.
BLOWERS
Centrifugal type rated at 1200 cfm (566 L/s) free air delivery. Each air
stream has one double shafted motor driving a centrifugal blower.
CONNECTION DUCT SIZES
Four - 20" x 8" (508 mm x 200 mm).
MOUNTING
Unit to be set on support brackets hung by threaded rod type apparatus.
(brackets and rod not provided).
CASE
20 gauge prepainted galvanized steel (G60) for superior corrosion
resistance. Insulated with foil faced insulation where required to prevent
exterior condensation.
CONTROLS
Illuminated power switch, 3 speed blower control, low voltage (24 VAC)
terminals for connection of remote controls.
WEIGHT 191 lbs. (87 kg) SHIPPING WEIGHT 215 lbs. (98 kg)

29 7/8" (759 mm)

8"

(200 mm)

FRONT VIEW

24 5/8 "

(625 mm)

41 1/2"

(1055 mm)

20"

(508 mm)

6 3/4"

(172 mm)

INLET SIDE

DIMENSIONS 1200

inches (mm)

8"

(200 mm)

41 1/2"

(1055 mm)

20"

(508 mm)

5 7/8"

(159 mm)

CONTROLS

DISCHARGE SIDE

EXHAUST AIR

TO OUTSIDE

EXHAUST AIR

FROM BUILDING

SUPPLY AIR

TO BUILDING

SUPPLY AIR

FROM OUTSIDE

NOTE:

Service clearance
is 30 in. (760 mm)
from front
access doors.

HEAT RECOVERY VENTILATORS (HRVs)

¤

10 3/8"

(263 mm)

10 3/8"

(263 mm)

OPTIONS

99-101

Sixty Minute Remote Timer

99-130

Remote Wall Mount Dehumidistat Control
24 VAC only, W (white) or B (beige)

All units conform to CSA and UL standards.

WARRANTY

Units carry a 5 year warranty on the energy recovery cores and 2
year replacement parts warranty.

It is recommended for regions where the temperature does
not fall below 25°F (-4°C).

DATE:

________________

UNIT SELECTED:

_____________

PROJECT:

________________________________________

MECHANICAL CONTRACTOR:

__________________________

AIRFLOWS (Each Air Stream)

613 (1300)

566 (1200)

518 (1100)

472 (1000)

423 (900)

378 (800)

329 (700)

282 (600)

235 (500)

AIRFLOW L/s (CFM)

25 (.1) 50 (.2) 75 (.3) 100 (.4) 125 (.5) 150 (.6) 175 (.7)

EXTERNAL STATIC PRESSURE IN PASCALS (in. W.C.)

TOTAL CURRENT DRAW (AMPS) @ 120 VAC

7.8 MED

8.1 HIGH

7.1 LOW

70%

60%

50%

500

(235)

600

(282)

700

(329˚)

TEMPERATURE EFFECTIVENESS

AIRFLOW IN L/s (CFM)

NOTE: Exhaust Relative Humidity (RH) at 40%

EFFECTIVENESS

HIGH SPEED

MED SPEED

LOW SPEED

800

(378)

900

(423)

1000

(472)

1200

(566)

1100

(518)

P E R F O R M A N C E

TI-132

9807

511 McCormick Boulevard
London, Ontario

Phone: (519) 457-1904
Fax: (519) 457-1676
E mail:[email protected]

500

(235)

600

(282)

700

(329)

800

(378)

900

(423)

1000

(472)

1100

(518)

1200

(566)