Start-up – Raypak RAYTHERM 133-4001 User Manual

Page 26

Advertising
background image

26

1. Set the thermostat to lowest setting.
2. Turn off all electric power to the appliance.
3. Remove boiler door.

4. Push in gas control knob slightly and turn clock-

wise

to “OFF”. Do not force.

5. Replace boiler door panel.

1. STOP! Read the safety information above on

this label.

2. Set the thermostat to lowest setting.
3. Turn off all electric power to the appliance.
4. Remove boiler door panel.
5. Push in gas control knob slightly and turn

clockwise

to “OFF”.

NOTE: Knob cannot be turned from “PILOT” to “OFF”
unless knob is pushed in slightly. Do not force.

6. Wait five (5) minutes to clear out any gas. Then

smell for gas, including near the floor. If you
smell gas, STOP! Follow “B” in the safety in-
formation above on this label. If you don’t smell
gas, go to next step.

7. Locate pilot mounted

on the right side of the
burner tray, and right
of first burner.

8. Turn knob on gas control

counter-clockwise
to "PILOT"

9. Push in control knob all the way and hold in .

Immediately light the pilot with a match. Continue
to hold the control knob in for about one (1) minute
after the pilot is lit. Release knob and it will pop
back up. Pilot should remain lit. If it goes out, re-
peat steps 5 through 9.

If knob does not pop up when released, stop
and immediately call your service technician
or gas supplier.

If the pilot will not stay lit after several tries,
turn the gas control knob to “OFF” and call
your service technician or gas supplier.

10. Stand to the side of the boiler and turn the gas

control knob counter-clockwise

to "ON".

11 Replace boiler door panel.
12. Turn on all electric power to the appliance.
13 Set the thermostat to the desired setting.

PILOT

THERMO-

BURNER

COUPLE

A. This appliance has a pilot which must be lighted

by hand. When lighting the pilot, follow these
instructions exactly.

B. BEFORE LIGHTING smell all around the appli-

ance area for gas. Be sure to smell next to the
floor because some gas is heavier than air and
will settle on the floor.

WHAT TO DO IF YOU SMELL GAS

Do not try to light any appliance.

Do not touch any electric switch; do not use
any phone in your building.

Immediately call your gas supplier from a
neighbor’s phone. Follow the gas supplier’s
instructions.

If you cannot reach your gas supplier, call
the fire department.

C. Use only your hand to push in or turn the gas

control knob. Never use tools. If the knob will
not push in or turn by hand, don’t try to repair it,
call a qualified service technician. Force or at-
tempted repair may result in a fire or explosion.

D. Do not use this appliance if any part has been

under water. Immediately call a qualified
service technician to inspect the appliance and
to replace any part of the control system and
any gas control which has been under water.

WARNING: If you do not follow these instructions exactly, a fire or explosion may
result causing property damage, personal injury or loss of life.

START-UP

LIGHTING INSTRUCTIONS FOR BOILERS WITH STANDING PILOT. For Models 133, 182, 260, 330 & 400

GAS CONTROL
KNOB SHOWN
IN "OFF"
POSITION

GAS INLET

GAS CONTROL
KNOB SHOWN
IN "OFF"
POSITION

GAS INLET

TO TURN OFF GAS TO APPLIANCE

LIGHTING INSTRUCTIONS

FOR YOUR SAFETY READ BEFORE LIGHTING

Advertising