RECEIVING EQUIPMENT

On receipt of the equipment, visually check for exter-

nal damage to the carton or the shipping crate. If either

is damaged, make a note on the Bill of Lading and

report the damage to the Carrier immediately. Remove

the boiler from the carton or the shipping crate.

On occasion, items are shipped loose. Be sure that

you receive the number of packages indicated on the

Bill of Lading.

When ordering parts, you must specify the Model and

Serial Number of the boiler. When ordering under war-

ranty conditions, you must also specify the date of

installation.

Raypak recommends that this manual be reviewed

thoroughly before installing your Raypak boiler. If there

are any questions which this manual does not answer,

please contact the factory or your local Raypak repre-

sentative.

Claims for shortages and damages must be filed with

carrier by consignee. Permission to return goods must

be factory authorized and are subject to a stocking

charge.

Purchased parts are subject to replacement only

under the manufacturer's warranty. Debits for defec-

tive replacement parts will not be accepted and will be

replaced in kind only per our standard warranties.

CERTIFICATIONS

The Raypak hydronic boilers are design certified and

tested under the latest requirements of the American

National Standard, ANSI Z21.13. Each boiler has been

constructed and pressure tested in accordance with

the requirements of Section IV of the American Society

of Mechanical Engineers Code, and factory fire tested.

All models are National Board approved. Temperature

and pressure gauge is standard. Model 0133 has a 4-

pass heat exchanger, 1 tube per pass. Models

0181-1826 have 2-pass heat exchangers, 5 tubes first

pass, 4 tubes second pass. Models 2100-4001 have

2-pass heat exchangers, 9 tubes per pass. Models

926-4001 have optional single-pass heat exchangers

with cast iron headers only.

BOILER TYPES

Type H1 - Mechanical

Modulating, Models 133-1826

Central heating boiler with 150°-210°F mechanical

modulating gas valve(s). The number of valves varies

with the model size.

Type H2 - Motorized

Modulating, Models 514-4001

Central heating boiler with a motorized modulating gas

valve. Modulating controller optional.

Type H3 - 2-Stage Controls,

Models 181-4001

Central heating boiler with single 2-stage gas valve

and optional 2-stage controller.

Type H4 - On-Off Controls,

Models 181-4001

Central heating boiler with on-off firing.

Type H5 - Mechanical

Modulating, Models 181-1826

Central heating boiler with 110°-170°F mechanical

modulating gas valve(s).

Type H9 - 4-Stage, Models 514-

4001

Central heating boiler with 4-stage firing. Controller

optional.