Parameter list

These are settings that apply to the entire SH-201.

MIDI parameters

SYSTEM COMMON parameters

Parameter

Value

Explanation

Panel operation

MASTER LEVEL

0–127

Determines the overall volume of the SH-
201.

MASTER TUNE

415.30–
466.20 (Hz)

Tunes the entire SH-201. Specified in terms
of the frequency of the A4 key.

Hold down the CANCEL button and turn the PITCH knob

MASTER KEY
SHIFT

-24– +24

Shifts the pitch of the entire SH-201 upward
or downward in semitone steps.

PATCH
REMAIN

OFF, ON

If this is “ON,” the sound of the currently
sounding patch will be maintained when
you select a different patch.

1.

Hold down the CANCEL button and press the TAP button

2.

Press the PRESET button and then press the BANK D button

3.

Press the NUMBER 1 button

Lit:

ON,

Dark:

OFF

4.

Press the CANCEL button

CLOCK
SOURCE

PATCH,
SYSTEM,
MIDI, USB

Selects the synchronization source for the
arpeggiator/recorder tempo.

PATCH:

Synchronize to the tempo saved

in each patch (PATCH TEMPO, p. 64).

SYSTEM:

Synchronize to the tempo that

is common to the entire SH-201 system
(SYSTEM TEMPO).

MIDI:

Synchronize to MIDI messages re-

ceived via the MIDI IN connector.

USB:

Synchronize to MIDI messages re-

ceived via the USB connector.

1.

Hold down the CANCEL button and press the TAP button

2.

Press the PRESET button and then press the BANK B button

3.

Press a NUMBER button (1–4)

1:

PATCH,

2:

SYSTEM,

3:

MIDI,

4:

USB

4.

Press the CANCEL button

* Don’t set this to “MIDI” or “USB” unless you need to syn-

chronize the SH-201 to the MIDI clock from an external de-
vice. With these settings, the arpeggiator, recorder, tempo-
synchronized LFO, etc., will not work correctly.

SYSTEM
TEMPO

5–300
(BPM)

This is the common tempo value used by the
entire SH-201 when the CLOCK SOURCE
parameter (see above) is set to “SYSTEM.”

With the CLOCK SOURCE parameter set to “SYSTEM,” press
the TEMPO buttons or press the TAP button three or more
times at quarter-note intervals of the desired tempo (p. 22, p.
26).

Parameter

Value

Explanation

Panel operation

RX/TX CHANNEL

1–16

Specifies the MIDI channel on which the SH-201 will
transmit and receive MIDI messages.

1.

Hold down the CANCEL button and
press the TAP button

2.

Press the PRESET button and then press
the BANK A button

3.

Press a NUMBER button (1–8)

1–8 (Lit in red):

1–8

1–8 (Lit in green):

9–16

4.

Press the CANCEL button

MIDI-USB THRU

OFF, ON

If this is “ON,” MIDI messages received at the MIDI IN
connector will be re-transmitted without change from
the USB connector.

1.

Hold down the CANCEL button and
press the TAP button

2.

Press the PRESET button and then press
the BANK C button

3.

Press a NUMBER button (1, 2)

1:

MIDI-USB THRU

2:

SOFT THRU

Lit:

ON,

Dark:

OFF

4.

Press the CANCEL button

SOFT THRU

OFF, ON

If this is “ON,” MIDI messages received at the MIDI IN
connector will be re-transmitted without change from
the MIDI OUT connector.

RECEIVE SWITCH

PROGRAM
CHANGE

OFF, ON

If this is “ON,” the patch number or the patch bank (A–
D) will change when a program change message is re-
ceived.

1.

Hold down the CANCEL button and
press the TAP button

2.

Press the PRESET button and then press
the BANK C button

3.

Press a NUMBER button (3, 4)

3:

PROGRAM CHANGE

4:

BANK SELECT

Lit:

ON,

Dark:

OFF

4.

Press the CANCEL button

BANK SELECT

OFF, ON

If this is “ON,” the patch group (PRESET/USER) will
change when a MIDI bank select message is received.