SECTION 15: R

EMOVAL

AND

R

EPLACEMENT

P

ARTS

29

15.4 Flue Fan Vertical Installation

IT IS IMPORTANT THAT ONLY THE CORRECT FLUE FAN SPECIFIED FOR EACH MODEL TYPE IS
USED WHEN REPLACING THESE ITEMS.

Carry out a commission after working on or changing a flue fan. See Page 18, Section 11.

MODEL

CTCU-7

CTCU-11

CTCU-15

CTCU-22

CTCU-27

CTCU-32

Flue Fan

Fasco

7021-11767

Fasco

7021-11768

Fasco

7021-11769

Torin

S6818

Sit Controls

P1210838

Sit Controls

P1210838

RG P/N

90710470

90710470

90710470

90710460

90710460

90710460

Air Plate mm Ø

35

44

57

64

109.2

109.2

in Ø

1.38

1.75

2.25

2.50

4.3

4.3

RG P/N

11111210

11112210

11113210

11114210

11115210

11115210

Gasket

Mounting Plate

to Vent Box

fixing screws

Intake &

Exhaust

Covers

Air Intake Adapter

Flexible Duct

Vent Box

Gaskets

Mounting Plate

to Vent Box

fixing screws

Mounting Plate

to Flue Fan

fixing screws

Air Intake

Adapter

Intake &

Exhaust Covers

To remove the fan, remove 3
screws securing the fan and
mounting plate to the vent box.

To remove the fan from the
mounting plate, remove the 4
screws.

Refit in reverse order.

To change the flue and air
intake orientation from back to
top, remove the fan and
mounting plate as above.

Remove intake and exhaust
covers from top of the heater.

Rotate the fan, mounting plate
and gasket clockwise until the
flue adapter lines up with the
top hole. Secure with 3 screws.

Remove the flexible duct from
the air intake adapter on the
back.

Remove the air intake adapter
from the back of the heater and
install in the appropriate hole on
top. Reconnect the flexible duct.

Install intake and exhaust
covers over the back holes.

Ensure sealed joints.
Ensure mounting plate orifice is
clear and not obstructed.