Warning, Heater – Roberts Gorden CTCU 27 User Manual

Page 40

Advertising
background image

www.rg-inc.com

Printed in U.S.A.

Attach this information to the wall near the ROBERTS GORDON

®

heater

Installation Code and Annual Inspections: All installations and service of ROBERTS GORDON

®

products must be performed by a contractor qualified in the installation and service of products sold and supplied by Roberts-Gordon and conform to all

requirements set forth in the ROBERTS GORDON

®

manuals and all applicable governmental authorities pertaining to the installation, service and operation of the equipment. To help facilitate optimum performance and safety, Roberts-Gordon recommends

that a qualified contractor annually inspect your ROBERTS GORDON

®

products and perform service where necessary, using only ROBERTS GORDON

®

replacement parts.

Further Information: Applications, engineering and detailed guidance on systems design, installation and product performance is available through ROBERTS GORDON

®

representatives.

Please contact us for any further information you may require, including the Installation, Operation and Service Manual.

This product is not for residential use.

This document is intended to assist licensed professionals in the exercise of their professional judgement.

© 2006 Roberts-Gordon, LLC All rights reserved. No part of this work covered by the copyrights herein may be reproduced or copied in any form or by any means – graphic, electronic, or mechanical, including photocopying, recording, taping, or information storage

and

retrieval systems – without written permission of Roberts-Gordon, LLC.

Read the installation, Commissioning, Operation and Service Manual thoroughly before installation, operation or service.

OPERATING INSTRUCTIONS

1. STOP! Read all safety instructions on this information sheet.

2. Open the manual gas valve in the heater supply line.

3. Turn on electric power to the heater.

4. Set the thermostat to desired setting (above ambient temperature).

The automatic starting sequence begins.

NOTE: Following long shutdown periods, the burner control may go to

to 'LOCKOUT' during the start sequence. Push the reset button to

recommence firing. Contact service department if 'LOCKOUT'

continues (see manual for details).

1. Turn the thermostat/time switch to 'OFF'. The burner will turn 'OFF'

immediately, but fans will continue to cool heat exchanger until the fan

thermostat switches off.

1. Set the thermostat to off or the lowest setting.

2. Turn off electric power to the heater.

3. Turn off the manual gas valve in the heater supply line.

4. Call your registered installer/contractor qualified in the installation

and service of gas-fired heating equipment.

IF THE HEATER WILL NOT OPERATE, TO ENSURE YOUR SAFETY,

FOLLOW THESE INSTRUCTIONS TO SHUT DOWN YOUR HEATER

Fire Hazard

Some objects can catch fire or explode when placed

close to heater.

Keep all flammable objects, liquids and vapors the

required clearances to combustibles away from heater.

Failure to follow these instructions can result in death,

injury or property damage.

TO TURN OFF THE HEATER

Service Telephone: +44(0) 1902 498733

Service Fax: +44(0) 1902 401464

E-mail: [email protected]

E-mail: [email protected]

Roberts-Gordon, LLC

1250 William Street

P.O. Box 44

Buffalo, NY 14240-0044 USA

Telephone: 716.852.4400

Fax: 716.852.0854

Toll Free: 800.828.7450

Roberts-Gordon Europe Limited

Oxford Street

Bilston, West Midlands WV14 7EG UK

Telephone: +44(0) 1902 494425

Fax: +44(0) 1902 403200

®

WARNING

50 cm**

10 cm

30 cm

15 cm

Clearances to Combustibles

Wall

Terminal

Roof Terminal

Air

Intake

Flue

15 cm

2.5 - 3.5 m*

3 m

25 cm

Installation Clearances

3 m

Roof Terminal

**80 cm is necessary to service heater

*Heaters may be mounted at a higher level if destratification fans are installed.