Roberts Gorden CTCU 27 User Manual

Page 37

Advertising
background image

SECTION 15: R

EMOVAL

AND

R

EPLACEMENT

P

ARTS

31

15.6 Ignition Control

The control plugs onto the gas valve. Pull out 12 pin
electrical connection. Pull out ignition cable and
flame probe cable noting their positions
Release screw securing control to gas valve.
Refit in reverse. Ensure correct location of ignition
and flame probe cables. Ensure that the earth
connection is made directly to the earth point on the
gas valve.

15.7 CTCUA Axial Fan/Guard/Motor Assembly

The axial fan unit for the CTCUA heater is
supplied completely assembled and balanced.

15.7.1 Fan Removal and Replacement

15.7.2 To Replace the Fan Assembly

To replace the fan assembly, reverse the procedure
shown above. Fit rubber washers to the guard
mountings to reduce vibration.

• Check that the fan blades are free to rotate

before turning on the power to the fan.

• Strictly comply with the colour code of the fan

wires to ensure correct operation. See Page 14,
Section 9.3
wiring diagram.

• Use only genuine ROBERTS GORDON

®

replacement parts.

15.8 Fan and Limit Thermostats

15.8.1 Removal and Replacement

1. Pull off the electrical connections to the

thermostat

2. Unscrew the two screws securing the

thermostat

3. Fit a new thermostat with two screws ensuring

that the correct temperature setting and type
are selected.
See Page 6, Section 4.3.

4. Reconnect the electrical connections and test

operation.

Remove the screws

and washers.

Description

Part Number

Axial Fan CTCU-7

11111910

Axial Fan CTCU-11

11111911

Axial Fan CTCU-15

11111920

Axial Fan CTCU-22

11111921

Axial Fan CTCU-27/32

11111922

Advertising