Retrotech DM-2A User Manual

Page 16

Advertising
background image

8

Retrotec Energy Innovations, Ltd.

DM-2A Mark II 2008-02-22

The keys labeled 0 through 9 and the decimal point can be used for inputting values when

needed. You’ll also notice there are four directional keys labeled with arrows as in 2, 4, 6, and
8 representing up, left, right, and down (respectively). Besides the numeric and directional
functions, keys also include these secondary functions:

M

Ode

The DM-2A mark II can display measurements and calculate results in

The DM-2A mark II can display measurements and calculate results in

a variety of units. The upper portion of the display screen (PrA) always shows
channel A pressure, while the lower display area can change according to the
channel B display or the current mode. Press M

Ode

continuously to cycle through

the selections made available from the Setup menu. Choose from these modes:

Flow Displays the calculated flow though the fan.

EqLA This displays the Equivalent Leakage Area, sometimes called the

Canadian ELA usually taken at 10 Pa .

EfLA Displays the Effective Leakage Area (EfLA), sometimes called the US or

LBL (Lawrence Berkeley Labs) ELA and taken at 4 Pa.

Air change Measures the air changes per hour. This mode requires that you

input the volume on the main screen.

Flow/Area Displays the flow divided by the area that you have input on the

main screen.

EqLA/Area Displays the equivalent leakage area (EqLA) divided by the area

that you have input on the main screen.

DM-2A Mark II Dual-Channel Pressure Gauge

User Manual