Retrotech DM-2A User Manual

Page 32

Advertising
background image

24

Retrotec Energy Innovations, Ltd.

DM-2A Mark II 2008-02-22

Let’s explore a typical connection procedure as a practical example. To set up the connections

required to use a Retrotec fan device, follow these simple steps:

1. Plug the yellow Ethernet cable into the port labeled Speed Control.

2. Plug the red and yellow tubes into the color-coded pressure ports on the top side of

the gauge (as shown next). Ensure the tubes are snugly connected to the ports.

3. Locate the end of the umbilical cord that includes the longest length of red pressure

tube. Using the connections at this end of the umbilical cord, plug the yellow
Ethernet cable into the port labeled Speed Control on the fan top.

4. If external power is needed for the gauge, plug the power jack into the port labeled

Power on the top of the gauge. External power is provided either by the AC adapter
attached to an on-site AC power source, or (if available) power available from the fan.

To continue the set up operation and connect your gauge to the Retrotec door fan, follow

these steps:

5. Attach the Ethernet-style control cable to the port labeled Speed Control on the top

panel of the fan.

6. Attach the yellow flow-pressure tube to the yellow port labeled Ref B (fan) on the top

panel of the fan.

7. Attach the power cord jack (if available) to the port labeled Power on the top panel of

the fan.

8. Plug the main AC power cord for the fan into an available power supply source and

attach the opposite end to the port on the fan top panel labeled Main Power.

DM-2A Mark II Dual-Channel Pressure Gauge

User Manual

3:

Connecting Your Gauge

Advertising